You are here:

Vibro-meter IOC4T 200-560-000-019 I/O Interface Card

Manufacturer:Vibro-Meter

model name:IOC4T 200-560-000-019

Country of Origin: Finland (FI)

Estonia (EE)

Customized: Yes

Minimum order quantity: 1 piece

Order multiplier: 1 piece

Part type: New

WhatsApp:15359213550
WeChat:15359213550

Vibro-meter IOC4T 200-560-000-019 I/O Interface Card

The I/O terminal board installed at the rear of the rack must be paired one-to-one with MPC4 (275-304-110-012), which is an interface board for sensor input, 4-20mA analog output, and protection trip relay dry contact output. MPC4 is located in the front (VME slot), and IOC4T is fixed directly behind MPC4 on the rack backplane. The two are used in pairs and cannot be operated separately, meeting API670 and SIL2 certification for unit protection.
Core channel specifications
Sensor signal access
4-channel dynamic signal input (corresponding to the 4 measurement channels of MPC4): raw signals from eddy current, velocity, and acceleration sensors
2-channel speed/key phase Tacho input
Onboard signal surge and EMI protection, on-site probe cable directly connected to IOC4T terminal block
4-channel programmable analog output (4-20mA/0-10V optional, software configuration)
Linear error ≤± 0.5%
Maximum current output load: 325 Ω; Voltage output load>100k Ω
4-channel independent protection relay output (RL1~RL4)
Single relay: NO/NC software configurable
Rated: 250VAC, 5A; Maximum breaking capacity 1250VA
Contact and coil insulation withstand voltage: 4000VAC; 1000VAC withstand voltage between contacts
Mechanical lifespan of relay: 15 × 10 ⁶ cycles; Electrical lifespan>10 ⁵ cycles
DSI Discrete Control Input (Digital Control Terminal)
AR alarm reset input
DB dangerous trip bypass input
TM threshold doubling (speed adaptive threshold) input
5~24VDC dry contact signal
Electrical and Power Consumption
Power supply: supplied by the rack backplane VME bus (from RPS6U power supply SIM-330A/SIM-275D-48),+5V/± 12V
Typical power consumption: Basic power consumption is about 1.5W, with an increase of about 0.25W for each 4-20mA enabled channel
Internal communication: IP interface, point-to-point communication with the previous MPC4 card
Environmental and mechanical specifications
Working temperature: -25 ℃~+70 ℃
Storage temperature: -40 ℃~+85 ℃
Humidity: 5%~95% non condensing, IEC60068 EMC industrial anti-interference
Installation location: ABE04x rack rear backplane, not front VME plug-in card
Weight: Approximately 0.3kg
Terminal: Screw type wiring terminal, direct connection of on-site cables
Core Function Description
On site sensor signals are summarized and sent to MPC4 for vibration/displacement/speed acquisition and calculation
The vibration, displacement, and clearance values calculated by MPC4 are outputted as 4-20mA to DCS through IOC4T
MPC4 local judgment warning/danger tripping, driving IOC4T relay dry contact, directly sending to external tripping circuit
Receive external dry contact instructions: alarm reset, trip bypass, threshold multiplier switching
Signal isolation, surge protection, isolation of strong electrical interference on site, protection of MPC4 precision measurement circuit
supporting relationship
1 MPC4 must be paired with 1 IOC4T, corresponding one by one, with slot positions paired in front and behind
Machine rack controller: CPUM (200-566-101-013)+IOCN (200-566-000-012)
Rack power supply: SIM-330A AC/SIM-275D-48 DC, back-end CEB103 power backplane
Document source: VM600 IOC4T Data Sheet DS-IOC4T en


Our products are widely used in CNC mechanical metallurgy, petroleum and natural gas, and petrochemical industries,

Chemical industry, paper and printing, textile printing and dyeing, machinery, electronic manufacturing, automobile manufacturing,
Plastic machinery, electricity, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution.
The quoted price is not the actual price. Please contact the shopkeeper before placing the order to confirm the price and delivery time!!!

Recommended other models:

Vibro-meter SIM-275D-48 200-582-300-011 Power Supply Module

Vibro-meter 204-691-000-021 Vibration Processor Module

Vibro-meter 200-570-000-111 Processor Module

Vibro-meter 200-560-000-113 Processor Module

Vibro-meter 200-595-100-014 Processor Module

Vibro-meter 200-500-110-014 System Rack

Vibro-meter 204-040-100-012 System Rack

 

 

Contact information:+86 15359213550

1. A-B Rockwell
2. FOXBORO
3. TRNEX
4. OVATION Westinghouse
5. SCHNEIDER
6. GE FANUC Fanuc
7. SIEMENS
8. REXROTH INDRAMA
9. ABB
10. HONEYWELL
11. BENTLY NEVADA
12. YOKOGAWA Yokogawa
13. ICS TRIPLEX
14. BACHMANN
15. Emerson
16. EPRO
17. HIMA Black Horse and other imported industrial components!

Related models:

810-068158-013 810-082745-003 810-234640-213 853-049542-173
810-068158-014 810-099175-011 810-270556-001 853-064887-006
810-069751-103 810-102361-222 810-495586-001 853-064887-402
810-069751-114 810-17030-005 810-800031-300 853-286086-100
810-072907-005 810-17059-1 810-800081-005 853-801876-015
810-073479-215 810-17082-001 810-800081-018 880-12537-101

 

contact information:

Email: changxin2025@gmail.com