BENTLY 3500/65-01-00 Channel Temperature Monitor
The Bently Nevada™ 3500/65 Temperature Monitor provides 16 channels of precise temperature measurement for critical industrial monitoring applications. It supports both Resistance Temperature Detectors (RTDs) and isolated-tip Thermocouples (TCs), conditioning their signals and comparing measured values against user-programmable alarm setpoints for protection and process control.
Configuration is performed through the 3500 Rack Configuration Software, allowing users to define channel types, alarm settings, and operational parameters.
Each 16-channel module can be configured for:
Isolated tip thermocouples
3-wire RTDs
4-wire RTDs
Or a combination of RTD and TC inputs
In Triple Modular Redundant (TMR) systems, temperature monitors must be installed in groups of three adjacent modules. In this mode, the system applies dual voting logic to ensure high reliability, accurate operation, and immunity to single-point failures.
Technical Specifications
Inputs
| Parameter | Description |
|---|---|
| Channels | 16 channels of temperature measurement |
| Transducer Types | RTD and isolated-tip Thermocouple (TC) |
| Input Impedance | > 1 MΩ for each lead input |
| Power Consumption | 3 W (nominal) |
| Configuration | Performed via 3500 Rack Configuration Software |
Transducer Compatibility
| Transducer Type | Material / Standard | Temperature Range | Temperature Range (°F) |
|---|---|---|---|
| Thermocouples (TC) | |||
| Type E | Chromel–Constantan | –100 °C to +1000 °C | –148 °F to +1832 °F |
| Type J | Iron–Constantan | 0 °C to +760 °C | 32 °F to +1400 °F |
| Type K | Chromel–Alumel | 0 °C to +1370 °C | 32 °F to +2498 °F |
| Type T | Copper–Constantan | –160 °C to +400 °C | –256 °F to +752 °F |
| Resistance Temperature Detectors (RTD) | |||
| 100 Ω Platinum (α = 0.00385), 3-wire/4-wire | IEC Standard | –200 °C to +850 °C | –328 °F to +1562 °F |
| 100 Ω Platinum (α = 0.00392), 3-wire/4-wire | US Industrial Standard | –200 °C to +700 °C | –328 °F to +1292 °F |
| 120 Ω Nickel, 3-wire/4-wire | — | –80 °C to +260 °C | –112 °F to +500 °F |
| 10 Ω Copper, 3-wire/4-wire | — | –100 °C to +260 °C | –148 °F to +500 °F |
Key Features
16 independent input channels for flexible configuration and multi-point monitoring
Supports mixed input types (RTD and TC) per module
High input impedance (>1 MΩ) for accurate and noise-resistant measurement
Programmable alarms for process protection and control integration
Triple Modular Redundancy (TMR) support with dual voting logic to prevent single-point failures
Software-configurable parameters via 3500 Rack Configuration Software for easy setup and maintenance
BENTLY 3500/65-01-00 Channel Temperature Monitor

Our products are widely used in CNC mechanical metallurgy, petroleum and natural gas, and petrochemical industries,
Chemical industry, paper and printing, textile printing and dyeing, machinery, electronic manufacturing, automobile manufacturing,
Plastic machinery, electricity, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution.
The quoted price is not the actual price. Please contact the shopkeeper before placing the order to confirm the price and delivery time!!!

Contact information:+86 15359213550
1. A-B Rockwell
2. FOXBORO
3. TRNEX
4. OVATION Westinghouse
5. SCHNEIDER
6. GE FANUC Fanuc
7. SIEMENS
8. REXROTH INDRAMA
9. ABB
10. HONEYWELL
11. BENTLY NEVADA
12. YOKOGAWA Yokogawa
13. ICS TRIPLEX
14. BACHMANN
15. Emerson
16. EPRO
17. HIMA Black Horse and other imported industrial components!
Related models:
| 136188-02 |
| 136483-01 |
| 138607-01 |
| 146031-01 |
| 146031-02 |
| 149992-01 |
| 167699-02 |
| 176449-08 |
| 1900/65A |
| 1900/65A-00-00-02-00-00 |
| 1900/65A-00-02-01-01-01 |
| 1900/65A-01-00-01-00-00 |
| 1900/65A-01-01-01-00-00 |
| 1900/65A-01-01-03-00-00 |
| 24765-01-01 |
| 288055-01 |
| 3500/01-01 |
| 3500/04 |
| 3500/05 |
| 3500/05-01-01-00-00-00 |
contact information:
Email: 3697824077@qq.com