BENTLY 3500/61-05-02 Temperature Monitors
Environmental Limits
| Condition | Description | Range |
|---|---|---|
| Operating Temperature | With Internal/External Termination I/O Modules | -30°C to +65°C (-22°F to +150°F) |
| With Internal Barrier I/O Modules (Internal Termination) | 0°C to +65°C (32°F to +150°F) | |
| Storage Temperature | — | -40°C to +85°C (-40°F to +185°F) |
Physical Specifications
Monitor Module
| Parameter | Specification |
|---|---|
| Dimensions (H × W × D) | 241.3 mm × 24.4 mm × 241.8 mm (9.50 in × 0.96 in × 9.52 in) |
| Weight | 0.91 kg (2.0 lb) |
I/O Modules
| Type | Dimensions (H × W × D) | Weight |
|---|---|---|
| Standard I/O Module | 241.3 mm × 24.4 mm × 99.1 mm (9.50 in × 0.96 in × 3.90 in) | 0.45 kg (1.0 lb) |
| I/O Module (Internal Barrier) | 241.3 mm × 24.4 mm × 163.1 mm (9.50 in × 0.96 in × 6.42 in) | 0.46 kg (1.01 lb) |
Rack Space Requirements
| Component | Slot Requirement |
|---|---|
| Monitor Module | One full-height front slot |
| I/O Module | One full-height rear slot |
Compliance and Certifications
(Approvals pending)
FCC
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
-
This device may not cause harmful interference.
-
This device must accept any interference received, including interference that may cause undesired operation.
EMC (Electromagnetic Compatibility)
European Community Directive: EMC Directive 2014/30/EU
Standards:
EN 61000-6-2 — Immunity for Industrial Environments
EN 61000-6-4 — Emissions for Industrial Environments
Electrical Safety
European Community Directive: Low Voltage Directive 2014/35/EU
Standard: EN 61010-1
RoHS Compliance
European Community Directive: RoHS Directive 2011/65/EU
BENTLY 3500/61-05-02 Temperature Monitors

Our products are widely used in CNC mechanical metallurgy, petroleum and natural gas, and petrochemical industries,
Chemical industry, paper and printing, textile printing and dyeing, machinery, electronic manufacturing, automobile manufacturing,
Plastic machinery, electricity, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution.
The quoted price is not the actual price. Please contact the shopkeeper before placing the order to confirm the price and delivery time!!!

Contact information:+86 15359213550
1. A-B Rockwell
2. FOXBORO
3. TRNEX
4. OVATION Westinghouse
5. SCHNEIDER
6. GE FANUC Fanuc
7. SIEMENS
8. REXROTH INDRAMA
9. ABB
10. HONEYWELL
11. BENTLY NEVADA
12. YOKOGAWA Yokogawa
13. ICS TRIPLEX
14. BACHMANN
15. Emerson
16. EPRO
17. HIMA Black Horse and other imported industrial components!
Related models:
| 136188-02 |
| 136483-01 |
| 138607-01 |
| 146031-01 |
| 146031-02 |
| 149992-01 |
| 167699-02 |
| 176449-08 |
| 1900/65A |
| 1900/65A-00-00-02-00-00 |
| 1900/65A-00-02-01-01-01 |
| 1900/65A-01-00-01-00-00 |
| 1900/65A-01-01-01-00-00 |
| 1900/65A-01-01-03-00-00 |
| 24765-01-01 |
| 288055-01 |
| 3500/01-01 |
| 3500/04 |
| 3500/05 |
| 3500/05-01-01-00-00-00 |
contact information: